Lumenwerx · Pendant
Flair Cylinder
35 fixtures
7 × 5 grid · achieves ≈ 35 fc
- Output
- 2,145 lm
- Efficacy
- 107 lm/W
- Power density
- 0.58 W/ft²
Lighting tools
Describe your space and target light level, and this tool ranks real fixtures from the catalog by how well they fit — showing the exact number of fixtures (with a suggested grid) or the feet of continuous linear run you'd need for each, computed with the lumen method. Filter by category and manufacturer to shortlist candidates, then open any product for full specs and IES files.
286 point fixtures matched — ranked for 35 fc over 1,200 ft².
Lumenwerx · Pendant
35 fixtures
7 × 5 grid · achieves ≈ 35 fc
ON LIGHT · Downlight
42 fixtures
7 × 6 grid · achieves ≈ 35 fc
ON LIGHT · Downlight
42 fixtures
7 × 6 grid · achieves ≈ 35 fc
Axis Lighting · Sconce
42 fixtures
7 × 6 grid · achieves ≈ 35 fc
aaline · Pendant
63 fixtures
9 × 7 grid · achieves ≈ 35 fc
aaline · Pendant
63 fixtures
9 × 7 grid · achieves ≈ 35 fc
aaline · Sconce
63 fixtures
9 × 7 grid · achieves ≈ 35 fc
aaline · Pendant
63 fixtures
9 × 7 grid · achieves ≈ 35 fc
Axis Lighting · Pendant
63 fixtures
9 × 7 grid · achieves ≈ 35 fc
Folio · Panel Light
108 fixtures
12 × 9 grid · achieves ≈ 35 fc
OCL Architectural Lighting · Pendant
20 fixtures
5 × 4 grid · achieves ≈ 35 fc
Insight Lighting · Flood Light
9 fixtures
3 × 3 grid · achieves ≈ 35 fc
Folio · Panel Light
4 fixtures
2 × 2 grid · achieves ≈ 35 fc
Folio · Panel Light
80 fixtures
10 × 8 grid · achieves ≈ 35 fc
Lumenwerx · Sconce
1900 fixtures
50 × 38 grid · achieves ≈ 35 fc
Insight Lighting · Sconce
9 fixtures
3 × 3 grid · achieves ≈ 36 fc
OCL Architectural Lighting · Pendant
12 fixtures
4 × 3 grid · achieves ≈ 36 fc
Focal Point · Troffer
9 fixtures
3 × 3 grid · achieves ≈ 36 fc
ON LIGHT · Track
9 fixtures
3 × 3 grid · achieves ≈ 36 fc
Axis Lighting · Troffer
9 fixtures
3 × 3 grid · achieves ≈ 36 fc
OCL Architectural Lighting · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 36 fc
Axis Lighting · Pendant
70 fixtures
10 × 7 grid · achieves ≈ 36 fc
aaline · Linear
35 fixtures
7 × 5 grid · achieves ≈ 36 fc
Lumenwerx · Pendant
12 fixtures
4 × 3 grid · achieves ≈ 36 fc
Lumenwerx · Pendant
12 fixtures
4 × 3 grid · achieves ≈ 36 fc
Axis Lighting · Track
48 fixtures
8 × 6 grid · achieves ≈ 36 fc
Lumenwerx · Downlight
208 fixtures
16 × 13 grid · achieves ≈ 36 fc
OCL Architectural Lighting · Pendant
20 fixtures
5 × 4 grid · achieves ≈ 36 fc
OCL Architectural Lighting · Pendant
20 fixtures
5 × 4 grid · achieves ≈ 36 fc
Insight Lighting · Pendant
20 fixtures
5 × 4 grid · achieves ≈ 36 fc
aaline · Pendant
70 fixtures
10 × 7 grid · achieves ≈ 36 fc
Lumenwerx · Pendant
70 fixtures
10 × 7 grid · achieves ≈ 36 fc
Axis Lighting · Track
154 fixtures
14 × 11 grid · achieves ≈ 36 fc
Axis Lighting · Sconce
70 fixtures
10 × 7 grid · achieves ≈ 36 fc
Finelite · Troffer
4 fixtures
2 × 2 grid · achieves ≈ 36 fc
Meteor Lighting · Pendant
12 fixtures
4 × 3 grid · achieves ≈ 36 fc
OCL Architectural Lighting · Pendant
42 fixtures
7 × 6 grid · achieves ≈ 36 fc
ILEX · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 36 fc
ILEX · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 36 fc
ILEX · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 36 fc
ILEX · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 36 fc
ILEX · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 36 fc
ILEX · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 36 fc
ILEX · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 36 fc
Amerlux · Downlight
48 fixtures
8 × 6 grid · achieves ≈ 36 fc
Focal Point · Troffer
6 fixtures
3 × 2 grid · achieves ≈ 36 fc
ILEX · Pendant
6 fixtures
3 × 2 grid · achieves ≈ 36 fc
ILEX · Pendant
6 fixtures
3 × 2 grid · achieves ≈ 36 fc
Axis Lighting · Troffer
6 fixtures
3 × 2 grid · achieves ≈ 36 fc
ILEX · Pendant
30 fixtures
6 × 5 grid · achieves ≈ 36 fc
Lumenwerx · Downlight
48 fixtures
8 × 6 grid · achieves ≈ 36 fc
Lumenwerx · Pendant
130 fixtures
13 × 10 grid · achieves ≈ 36 fc
Axis Lighting · Track
130 fixtures
13 × 10 grid · achieves ≈ 36 fc
OCL Architectural Lighting · Pendant
12 fixtures
4 × 3 grid · achieves ≈ 37 fc
Insight Lighting · Cove
20 fixtures
5 × 4 grid · achieves ≈ 37 fc
OCL Architectural Lighting · Pendant
63 fixtures
9 × 7 grid · achieves ≈ 37 fc
Lithonia Lighting · Panel Light
12 fixtures
4 × 3 grid · achieves ≈ 37 fc
Folio · Linear
20 fixtures
5 × 4 grid · achieves ≈ 37 fc
OCL Architectural Lighting · Pendant
4 fixtures
2 × 2 grid · achieves ≈ 37 fc
Lumenwerx · Pendant
88 fixtures
11 × 8 grid · achieves ≈ 37 fc
Lumenwerx · Downlight
63 fixtures
9 × 7 grid · achieves ≈ 37 fc
OCL Architectural Lighting · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 37 fc
Insight Lighting · Cove
56 fixtures
8 × 7 grid · achieves ≈ 37 fc
Folio · Sconce
99 fixtures
11 × 9 grid · achieves ≈ 37 fc
ON LIGHT · High Bay
2 fixtures
2 × 1 grid · achieves ≈ 37 fc
Meteor Lighting · Pendant
20 fixtures
5 × 4 grid · achieves ≈ 37 fc
ON LIGHT · Track
20 fixtures
5 × 4 grid · achieves ≈ 37 fc
Picasso Lighting · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 37 fc
Picasso Lighting · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 37 fc
ON LIGHT · Pendant
20 fixtures
5 × 4 grid · achieves ≈ 37 fc
Focal Point · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 37 fc
Meteor Lighting · Downlight
20 fixtures
5 × 4 grid · achieves ≈ 37 fc
Picasso Lighting · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 37 fc
Lumenwerx · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 37 fc
Axis Lighting · Downlight
80 fixtures
10 × 8 grid · achieves ≈ 37 fc
Picasso Lighting · Pendant
80 fixtures
10 × 8 grid · achieves ≈ 37 fc
Axis Lighting · Downlight
48 fixtures
8 × 6 grid · achieves ≈ 38 fc
Insight Lighting · Flood Light
16 fixtures
4 × 4 grid · achieves ≈ 38 fc
Lumenwerx · Pendant
35 fixtures
7 × 5 grid · achieves ≈ 38 fc
OCL Architectural Lighting · Linear
16 fixtures
4 × 4 grid · achieves ≈ 38 fc
Folio · Panel Light
35 fixtures
7 × 5 grid · achieves ≈ 38 fc
Axis Lighting · Downlight
30 fixtures
6 × 5 grid · achieves ≈ 38 fc
Focal Point · Downlight
35 fixtures
7 × 5 grid · achieves ≈ 38 fc
Axis Lighting · Troffer
9 fixtures
3 × 3 grid · achieves ≈ 38 fc
Lumenwerx · Pendant
9 fixtures
3 × 3 grid · achieves ≈ 38 fc
OCL Architectural Lighting · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 38 fc
Lumenwerx · Pendant
180 fixtures
15 × 12 grid · achieves ≈ 38 fc
Lumenwerx · Downlight
48 fixtures
8 × 6 grid · achieves ≈ 38 fc
ON LIGHT · Linear
4 fixtures
2 × 2 grid · achieves ≈ 38 fc
Insight Lighting · Flood Light
12 fixtures
4 × 3 grid · achieves ≈ 38 fc
OCL Architectural Lighting · Sconce
42 fixtures
7 × 6 grid · achieves ≈ 38 fc
Lumenwerx · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 38 fc
Lumenwerx · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 38 fc
OCL Architectural Lighting · Pendant
20 fixtures
5 × 4 grid · achieves ≈ 38 fc
OCL Architectural Lighting · Sconce
48 fixtures
8 × 6 grid · achieves ≈ 38 fc
Axis Lighting · Pendant
48 fixtures
8 × 6 grid · achieves ≈ 38 fc
aaline · Pendant
9 fixtures
3 × 3 grid · achieves ≈ 38 fc
ILEX · Sconce
63 fixtures
9 × 7 grid · achieves ≈ 38 fc
ILEX · Sconce
63 fixtures
9 × 7 grid · achieves ≈ 38 fc
OCL Architectural Lighting · Pendant
99 fixtures
11 × 9 grid · achieves ≈ 38 fc
Insight Lighting · Flood Light
35 fixtures
7 × 5 grid · achieves ≈ 38 fc
Meteor Lighting · Sconce
2 fixtures
2 × 1 grid · achieves ≈ 38 fc
Focal Point · Pendant
24 fixtures
6 × 4 grid · achieves ≈ 38 fc
OCL Architectural Lighting · Pendant
9 fixtures
3 × 3 grid · achieves ≈ 38 fc
OCL Architectural Lighting · Pendant
9 fixtures
3 × 3 grid · achieves ≈ 38 fc
OCL Architectural Lighting · Pendant
9 fixtures
3 × 3 grid · achieves ≈ 38 fc
Amerlux · Downlight
20 fixtures
5 × 4 grid · achieves ≈ 38 fc
Meteor Lighting · Pendant
9 fixtures
3 × 3 grid · achieves ≈ 38 fc
Insight Lighting · Area Light
16 fixtures
4 × 4 grid · achieves ≈ 38 fc
Folio · Pendant
20 fixtures
5 × 4 grid · achieves ≈ 39 fc
Lumenwerx · Downlight
30 fixtures
6 × 5 grid · achieves ≈ 39 fc
OCL Architectural Lighting · Pendant
130 fixtures
13 × 10 grid · achieves ≈ 39 fc
Axis Lighting · Linear
120 fixtures
12 × 10 grid · achieves ≈ 39 fc
OCL Architectural Lighting · Pendant
35 fixtures
7 × 5 grid · achieves ≈ 39 fc
ON LIGHT · Downlight
16 fixtures
4 × 4 grid · achieves ≈ 39 fc
Insight Lighting · Flood Light
63 fixtures
9 × 7 grid · achieves ≈ 39 fc
Folio · Pendant
20 fixtures
5 × 4 grid · achieves ≈ 39 fc
Lumenwerx · Downlight
72 fixtures
9 × 8 grid · achieves ≈ 39 fc
Meteor Lighting · High Bay
2 fixtures
2 × 1 grid · achieves ≈ 39 fc
Insight Lighting · Flood Light
42 fixtures
7 × 6 grid · achieves ≈ 39 fc
Picasso Lighting · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 39 fc
Focal Point · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 39 fc
Picasso Lighting · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 39 fc
Axis Lighting · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 39 fc
Axis Lighting · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 39 fc
Axis Lighting · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 39 fc
Picasso Lighting · Troffer
30 fixtures
6 × 5 grid · achieves ≈ 39 fc
Insight Lighting · Landscape
30 fixtures
6 × 5 grid · achieves ≈ 39 fc
Lumenwerx · Downlight
30 fixtures
6 × 5 grid · achieves ≈ 39 fc
Axis Lighting · Downlight
35 fixtures
7 × 5 grid · achieves ≈ 39 fc
ILEX · Sconce
42 fixtures
7 × 6 grid · achieves ≈ 39 fc
ILEX · Pendant
42 fixtures
7 × 6 grid · achieves ≈ 39 fc
ON LIGHT · Downlight
42 fixtures
7 × 6 grid · achieves ≈ 39 fc
ON LIGHT · Downlight
42 fixtures
7 × 6 grid · achieves ≈ 39 fc
ON LIGHT · Downlight
42 fixtures
7 × 6 grid · achieves ≈ 39 fc
ON LIGHT · Downlight
42 fixtures
7 × 6 grid · achieves ≈ 39 fc
Lumenwerx · Downlight
63 fixtures
9 × 7 grid · achieves ≈ 39 fc
OCL Architectural Lighting · Pendant
20 fixtures
5 × 4 grid · achieves ≈ 39 fc
Folio · Pendant
9 fixtures
3 × 3 grid · achieves ≈ 40 fc
Lumenwerx · Downlight
42 fixtures
7 × 6 grid · achieves ≈ 40 fc
Axis Lighting · Pendant
80 fixtures
10 × 8 grid · achieves ≈ 40 fc
Lumenwerx · Linear
80 fixtures
10 × 8 grid · achieves ≈ 40 fc
OCL Architectural Lighting · Pendant
56 fixtures
8 × 7 grid · achieves ≈ 40 fc
Insight Lighting · Linear
9 fixtures
3 × 3 grid · achieves ≈ 40 fc
OCL Architectural Lighting · Pendant
30 fixtures
6 × 5 grid · achieves ≈ 40 fc
Picasso Lighting · Pendant
63 fixtures
9 × 7 grid · achieves ≈ 40 fc
Picasso Lighting · Pendant
63 fixtures
9 × 7 grid · achieves ≈ 40 fc
Picasso Lighting · Pendant
63 fixtures
9 × 7 grid · achieves ≈ 40 fc
Insight Lighting · Sconce
63 fixtures
9 × 7 grid · achieves ≈ 40 fc
Picasso Lighting · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 40 fc
OCL Architectural Lighting · Pendant
4 fixtures
2 × 2 grid · achieves ≈ 40 fc
Folio · Pendant
25 fixtures
5 × 5 grid · achieves ≈ 40 fc
Insight Lighting · Linear
20 fixtures
5 × 4 grid · achieves ≈ 40 fc
aaline · Pendant
2 fixtures
2 × 1 grid · achieves ≈ 40 fc
Axis Lighting · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 40 fc
Axis Lighting · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 40 fc
Folio · Pendant
30 fixtures
6 × 5 grid · achieves ≈ 40 fc
Lumenwerx · Downlight
30 fixtures
6 × 5 grid · achieves ≈ 40 fc
Meteor Lighting · Downlight
12 fixtures
4 × 3 grid · achieves ≈ 40 fc
OCL Architectural Lighting · Pendant
56 fixtures
8 × 7 grid · achieves ≈ 41 fc
Focal Point · Downlight
30 fixtures
6 × 5 grid · achieves ≈ 41 fc
OCL Architectural Lighting · Linear
9 fixtures
3 × 3 grid · achieves ≈ 41 fc
Insight Lighting · Linear
36 fixtures
6 × 6 grid · achieves ≈ 41 fc
ON LIGHT · Track
25 fixtures
5 × 5 grid · achieves ≈ 41 fc
Picasso Lighting · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 41 fc
ON LIGHT · Downlight
12 fixtures
4 × 3 grid · achieves ≈ 41 fc
Meteor Lighting · Downlight
30 fixtures
6 × 5 grid · achieves ≈ 41 fc
Meteor Lighting · Downlight
12 fixtures
4 × 3 grid · achieves ≈ 41 fc
Folio · Linear
20 fixtures
5 × 4 grid · achieves ≈ 41 fc
Axis Lighting · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 41 fc
ON LIGHT · Linear
9 fixtures
3 × 3 grid · achieves ≈ 41 fc
OCL Architectural Lighting · Pendant
42 fixtures
7 × 6 grid · achieves ≈ 41 fc
OCL Architectural Lighting · Linear
42 fixtures
7 × 6 grid · achieves ≈ 41 fc
ON LIGHT · Downlight
42 fixtures
7 × 6 grid · achieves ≈ 41 fc
Focal Point · Downlight
30 fixtures
6 × 5 grid · achieves ≈ 41 fc
OCL Architectural Lighting · Pendant
9 fixtures
3 × 3 grid · achieves ≈ 41 fc
Meteor Lighting · Downlight
9 fixtures
3 × 3 grid · achieves ≈ 42 fc
Insight Lighting · Cove
25 fixtures
5 × 5 grid · achieves ≈ 42 fc
Lumenwerx · Pendant
16 fixtures
4 × 4 grid · achieves ≈ 42 fc
Lumenwerx · Pendant
42 fixtures
7 × 6 grid · achieves ≈ 42 fc
Insight Lighting · Flood Light
20 fixtures
5 × 4 grid · achieves ≈ 42 fc
aaline · Pendant
36 fixtures
6 × 6 grid · achieves ≈ 42 fc
ON LIGHT · High Bay
1 fixtures
1 × 1 grid · achieves ≈ 42 fc
Picasso Lighting · Panel Light
4 fixtures
2 × 2 grid · achieves ≈ 42 fc
Folio · Panel Light
6 fixtures
3 × 2 grid · achieves ≈ 42 fc
Axis Lighting · Troffer
9 fixtures
3 × 3 grid · achieves ≈ 42 fc
OCL Architectural Lighting · Pendant
9 fixtures
3 × 3 grid · achieves ≈ 42 fc
Picasso Lighting · Panel Light
9 fixtures
3 × 3 grid · achieves ≈ 42 fc
Picasso Lighting · Panel Light
9 fixtures
3 × 3 grid · achieves ≈ 42 fc
ON LIGHT · Linear
9 fixtures
3 × 3 grid · achieves ≈ 42 fc
Folio · Panel Light
9 fixtures
3 × 3 grid · achieves ≈ 42 fc
Axis Lighting · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 42 fc
Focal Point · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 42 fc
Focal Point · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 42 fc
Picasso Lighting · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 42 fc
Picasso Lighting · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 42 fc
Lumenwerx · Pendant
20 fixtures
5 × 4 grid · achieves ≈ 42 fc
Lumenwerx · Pendant
25 fixtures
5 × 5 grid · achieves ≈ 42 fc
ILEX · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 42 fc
Lumenwerx · Track
30 fixtures
6 × 5 grid · achieves ≈ 42 fc
ILEX · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 42 fc
ILEX · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 42 fc
Folio · Pendant
30 fixtures
6 × 5 grid · achieves ≈ 42 fc
Lumenwerx · Track
30 fixtures
6 × 5 grid · achieves ≈ 42 fc
ILEX · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 42 fc
Folio · Pendant
36 fixtures
6 × 6 grid · achieves ≈ 42 fc
ILEX · Sconce
36 fixtures
6 × 6 grid · achieves ≈ 42 fc
ILEX · Sconce
36 fixtures
6 × 6 grid · achieves ≈ 42 fc
Picasso Lighting · Panel Light
36 fixtures
6 × 6 grid · achieves ≈ 42 fc
Meteor Lighting · Sconce
9 fixtures
3 × 3 grid · achieves ≈ 42 fc
Insight Lighting · Flood Light
4 fixtures
2 × 2 grid · achieves ≈ 43 fc
Focal Point · Downlight
30 fixtures
6 × 5 grid · achieves ≈ 43 fc
OCL Architectural Lighting · Pendant
25 fixtures
5 × 5 grid · achieves ≈ 43 fc
Meteor Lighting · High Bay
4 fixtures
2 × 2 grid · achieves ≈ 43 fc
OCL Architectural Lighting · Sconce
20 fixtures
5 × 4 grid · achieves ≈ 43 fc
OCL Architectural Lighting · Sconce
20 fixtures
5 × 4 grid · achieves ≈ 43 fc
OCL Architectural Lighting · Sconce
20 fixtures
5 × 4 grid · achieves ≈ 43 fc
Axis Lighting · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 43 fc
OCL Architectural Lighting · Pendant
25 fixtures
5 × 5 grid · achieves ≈ 43 fc
aaline · Linear
16 fixtures
4 × 4 grid · achieves ≈ 43 fc
Picasso Lighting · Panel Light
25 fixtures
5 × 5 grid · achieves ≈ 43 fc
OCL Architectural Lighting · Pendant
12 fixtures
4 × 3 grid · achieves ≈ 43 fc
OCL Architectural Lighting · Sconce
30 fixtures
6 × 5 grid · achieves ≈ 43 fc
Amerlux · Downlight
30 fixtures
6 × 5 grid · achieves ≈ 43 fc
Lumenwerx · Downlight
20 fixtures
5 × 4 grid · achieves ≈ 44 fc
Finelite · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 44 fc
Folio · Linear
25 fixtures
5 × 5 grid · achieves ≈ 44 fc
ON LIGHT · Downlight
9 fixtures
3 × 3 grid · achieves ≈ 44 fc
Lumenwerx · Downlight
9 fixtures
3 × 3 grid · achieves ≈ 44 fc
OCL Architectural Lighting · Sconce
16 fixtures
4 × 4 grid · achieves ≈ 44 fc
Meteor Lighting · Downlight
9 fixtures
3 × 3 grid · achieves ≈ 45 fc
Lumenwerx · Downlight
20 fixtures
5 × 4 grid · achieves ≈ 45 fc
Lumenwerx · Pendant
4 fixtures
2 × 2 grid · achieves ≈ 45 fc
ILEX · Pendant
6 fixtures
3 × 2 grid · achieves ≈ 45 fc
Focal Point · Troffer
12 fixtures
4 × 3 grid · achieves ≈ 45 fc
Lumenwerx · Pendant
12 fixtures
4 × 3 grid · achieves ≈ 45 fc
OCL Architectural Lighting · Sconce
12 fixtures
4 × 3 grid · achieves ≈ 45 fc
OCL Architectural Lighting · Sconce
12 fixtures
4 × 3 grid · achieves ≈ 45 fc
Focal Point · Pendant
12 fixtures
4 × 3 grid · achieves ≈ 45 fc
Lumenwerx · Linear
12 fixtures
4 × 3 grid · achieves ≈ 45 fc
Focal Point · Troffer
16 fixtures
4 × 4 grid · achieves ≈ 45 fc
Focal Point · Troffer
16 fixtures
4 × 4 grid · achieves ≈ 45 fc
Picasso Lighting · Troffer
16 fixtures
4 × 4 grid · achieves ≈ 45 fc
Focal Point · Troffer
16 fixtures
4 × 4 grid · achieves ≈ 45 fc
Axis Lighting · Troffer
16 fixtures
4 × 4 grid · achieves ≈ 45 fc
Focal Point · Troffer
16 fixtures
4 × 4 grid · achieves ≈ 45 fc
aaline · Pendant
16 fixtures
4 × 4 grid · achieves ≈ 45 fc
OCL Architectural Lighting · Pendant
12 fixtures
4 × 3 grid · achieves ≈ 45 fc
OCL Architectural Lighting · Pendant
6 fixtures
3 × 2 grid · achieves ≈ 46 fc
OCL Architectural Lighting · Linear
16 fixtures
4 × 4 grid · achieves ≈ 46 fc
Focal Point · Pendant
6 fixtures
3 × 2 grid · achieves ≈ 46 fc
Lumenwerx · Troffer
9 fixtures
3 × 3 grid · achieves ≈ 46 fc
Folio · Pendant
12 fixtures
4 × 3 grid · achieves ≈ 46 fc
Insight Lighting · Linear
2 fixtures
2 × 1 grid · achieves ≈ 46 fc
ON LIGHT · Downlight
20 fixtures
5 × 4 grid · achieves ≈ 47 fc
Picasso Lighting · Panel Light
20 fixtures
5 × 4 grid · achieves ≈ 47 fc
ON LIGHT · Downlight
20 fixtures
5 × 4 grid · achieves ≈ 47 fc
Lumenwerx · Troffer
20 fixtures
5 × 4 grid · achieves ≈ 47 fc
Insight Lighting · Linear
6 fixtures
3 × 2 grid · achieves ≈ 47 fc
OCL Architectural Lighting · Pendant
2 fixtures
2 × 1 grid · achieves ≈ 47 fc
ILEX · Pendant
9 fixtures
3 × 3 grid · achieves ≈ 47 fc
ILEX · Pendant
9 fixtures
3 × 3 grid · achieves ≈ 47 fc
Meteor Lighting · Downlight
9 fixtures
3 × 3 grid · achieves ≈ 47 fc
Picasso Lighting · Panel Light
6 fixtures
3 × 2 grid · achieves ≈ 48 fc
Focal Point · Troffer
6 fixtures
3 × 2 grid · achieves ≈ 48 fc
Folio · Panel Light
9 fixtures
3 × 3 grid · achieves ≈ 48 fc
Meteor Lighting · Downlight
4 fixtures
2 × 2 grid · achieves ≈ 49 fc
Insight Lighting · Flood Light
9 fixtures
3 × 3 grid · achieves ≈ 50 fc
Lumenwerx · Troffer
6 fixtures
3 × 2 grid · achieves ≈ 50 fc
ON LIGHT · Linear
6 fixtures
3 × 2 grid · achieves ≈ 50 fc
ON LIGHT · Downlight
9 fixtures
3 × 3 grid · achieves ≈ 50 fc
Picasso Lighting · Panel Light
9 fixtures
3 × 3 grid · achieves ≈ 50 fc
Picasso Lighting · Panel Light
9 fixtures
3 × 3 grid · achieves ≈ 50 fc
Meteor Lighting · Downlight
4 fixtures
2 × 2 grid · achieves ≈ 52 fc
Lumenwerx · Troffer
9 fixtures
3 × 3 grid · achieves ≈ 53 fc
OCL Architectural Lighting · Pendant
4 fixtures
2 × 2 grid · achieves ≈ 53 fc
ON LIGHT · High Bay
4 fixtures
2 × 2 grid · achieves ≈ 56 fc
Lumenwerx · Pendant
4 fixtures
2 × 2 grid · achieves ≈ 56 fc
Meteor Lighting · High Bay
2 fixtures
2 × 1 grid · achieves ≈ 56 fc
Lithonia Lighting · High Bay
4 fixtures
2 × 2 grid · achieves ≈ 57 fc
Gardco · Area Light
2 fixtures
2 × 1 grid · achieves ≈ 58 fc
Meteor Lighting · High Bay
4 fixtures
2 × 2 grid · achieves ≈ 61 fc
Meteor Lighting · Linear
4 fixtures
2 × 2 grid · achieves ≈ 63 fc
OCL Architectural Lighting · Pendant
4 fixtures
2 × 2 grid · achieves ≈ 67 fc
Meteor Lighting · Flood Light
1 fixtures
1 × 1 grid · achieves ≈ 69 fc
Meteor Lighting · High Bay
2 fixtures
2 × 1 grid · achieves ≈ 69 fc
Estimate only — the lumen method gives an average, not a point-by-point calculation. Confirm uniformity with a photometric layout from the manufacturer's IES files before specifying.
Start from the target maintained light level for the task (foot-candles) and the room area, which sets the total lumens you need. Then compare fixtures that deliver those lumens efficiently in the mounting form your ceiling allows — recessed troffers or downlights for grid and drywall ceilings, or continuous linear systems for architectural runs. This recommender ranks real catalog fixtures by how well their quantity fits your target.
Divide the total required lumens — (foot-candles × area) ÷ (CU × LLF) — by a fixture’s delivered lumens, then round up. A 2×4 troffer at 4000–9000 lumens covers far more area per unit than a small downlight, so the count varies widely. Select “Point fixtures,” filter by category, and the tool shows the count and a suggested grid for each candidate.
Point fixtures (troffers, downlights, panels) are counted as whole units and laid out on a grid. Linear systems are specified in lumens per foot and cut to a total run length, so the tool solves them as feet of continuous run rather than a fixture count. Switch fixture form to compare each approach for your space.
The lumen method estimates the average illuminance a fixture layout delivers, not the level at any single point, and uses assumed coefficient-of-utilization and light-loss-factor values you can adjust. Use it to shortlist fixtures and quantities, then validate the final design with a point-by-point photometric layout built from the manufacturer’s IES files.